earth led terminals
Standards-compliant protective conductor distribution – compact, clearly marked, safe
Protective conductor terminals (PE terminals) are specifically designed for distributing protective conductors inside control cabinets. Unlike standard rail terminals, they are internally connected to the DIN rail – the protective conductor is distributed directly via the earthed mounting rail. The green-yellow marking is normatively required and makes PE terminals instantly identifiable at a glance. At WATT24 you'll find protective conductor terminals for all common conductor cross-sections – as single terminals and in multi-level versions.
- Comprehensive advice & support
- over 10,000 articles in the shop
- Shipping in 24 hours
- thousands of satisfied customers
KATHRIN BRANDT
Employee Purchasing from TroisdorfGreat advice and friendly service. I was helped immediately and competently with any questions. Gladly again.
OMAR NASER
Office Manager from Frankfurt a.M.Goods are well packaged and arrive safely, which is important to me. My mail was answered immediately.
RAINER SEIDEL
Master carpenter from WiesbadenHad to replace a lamp, but the same was no longer available. Great advice, found a suitable replacement and delivered it quickly.
What is a protective conductor terminal?
A protective conductor terminal is a specialised rail terminal for the standards-compliant distribution of protective conductors (PE) inside control cabinets. The key difference: unlike standard rail terminals, where the conductor is isolated from the DIN rail, a PE terminal creates a conductive connection to the mounting rail. The connected protective conductor is distributed directly via the earthed DIN rail – without additional bridging or external connections.
Protective conductor terminals are identified by their green-yellow marking, which is normatively required under IEC 60947-7-1 (VDE 0611-1). They are mounted on the 35 mm DIN rail (TS 35) and can be combined directly with standard rail terminals.
Protective conductor terminals at a glance
| Type | Feature | Typical application |
|---|---|---|
| PE terminal (standard) | Conductive connection to DIN rail, green-yellow | PE distribution in control cabinets, machines, plant |
| PE terminal with test point | Measuring point accessible for test probe | Systems subject to regular inspection (DGUV / periodic testing) |
| Two-level PE terminal | Two PE levels in one terminal | Space-saving PE distribution at high conductor density |
| Three-level PE terminal | Three PE levels in one terminal | Maximum wiring density, complex switchgear installations |
Selecting the right protective conductor terminal
Three criteria are key when choosing the right PE terminal:
- Conductor cross-section: The PE terminal must accommodate the cross-section of the connected protective conductor – typically 1.5 mm² to 16 mm², larger for main protective conductors
- Connection type: Screw connection (classic, tool-required) or spring-clamp connection (tool-free, faster for high volumes)
- Wiring density: For many PE conductors in a confined space, two-level or three-level PE terminals are worthwhile
Applications for protective conductor terminals
Protective conductor terminals are required wherever protective conductors need to be distributed and connected in a standards-compliant manner:
- Machine building: PE distribution for all protectively earthed components in the machine
- Building automation: Protective conductor connections for actuators, sensors, drives
- Industrial plant: Standards-compliant earthing in complex control cabinets
- Test systems: PE terminals with test point for straightforward periodic testing
Frequently asked questions about protective conductor terminals
Standard rail terminals isolate the conductor from the DIN rail. Protective conductor terminals are internally connected to the mounting rail – the protective conductor is distributed directly via the earthed DIN rail. PE terminals are also normatively marked in green-yellow (IEC 60947-7-1).
Yes. Since protective conductor terminals route the PE connection via the mounting rail, the DIN rail itself must be earthed. Without an earthed DIN rail, standards-compliant protective conductor distribution is not possible.
Depending on the version, protective conductor terminals cover conductor cross-sections from 1.5 mm² to 35 mm². The cross-section of the PE terminal must be at least equal to that of the connected protective conductor.
Yes. Protective conductor terminals are lined up directly next to standard rail terminals on the DIN rail. This creates a standards-compliant terminal strip with integrated PE distribution in a single run.
Protective conductor terminals must comply with IEC 60947-7-1 (in Germany: VDE 0611-1). This standard governs the green-yellow marking, minimum cross-sections, and the requirements for the connection to the mounting rail.
Buy protective conductor terminals at WATT24
At WATT24 you'll find protective conductor terminals for all common conductor cross-sections – as single terminals and in two-level and three-level versions, available for fast delivery at fair prices for electricians and commercial customers.